MSN MSN MSN MSN     
Position:Home > Products > Flow Indicator

  XST series single input channel instrument

1.     Summarize 

XST series intelligent digital instrumentation and all kinds of single input channel analog output of the sensor and transmitter, to realize the measurement, transform, display, transmission and control of temperature, pressure, flow, liquid level, composition , force and displacement.

1). Basic error is better than ±0.2% F. S.
2).16-bit A/D converter.
3). Measurement and control cycle is 0.2 seconds,  it can be increased to 0.1 seconds.
4). 8 section polyline function.
5). Display range: - 1999 ~ 9999
6).Anti-interference design, restrain the rapid pulse train interference and other electromagnetic interference from the scene of the relay and contactor, its anti-interference ability reaches the level III.
7). 10 kind of alarm including deviation and standby, it can  effectively prevent interference factors resulting the  false alarm delay function.

2.  Parameter selection table

Content

Code and introduction

XST/

Single display

Dimension

 A—

160(W)×80(H)×125(L) or 80(W)×160(H)×125(L)

 B—

96(W)×96(H)×112(L)

 C—

96(W)×48(H)×112(L) or 48(W)×96(H)×112(L)

 D—

72(W)×72(H)×112(L)

 E—

48(W)×48(H)×112(L)

Panel form

 H

Horizontal type

 S

Vertical type

 F

Square type

Display

 1

Measured values (green)

 2

Measured values (green)+ The set value (red)

 3

Measured values (green)+ Measured values light (green)(only for A、C type instrument)

Input signal

 E

Thermocouple K, S, R, B, N, E, J, T, or radiation heat meter

 R

Thermal resistance Pt100, Cu100, Cu50, BA1, BA2, G53 or resistance

 I

Direct current (4 ~ 20) mA , (0 ~ 10) or (0 ~ 20 ) mA

 V

Direct voltage (0~5)V、(1~5)V

 M

mV signal (please note the range when ordering)

 W

Potentiometer 500Ω-5000Ω

 L

Transmissible pressure gauge

Numbers of station

  T□

T0:alarm free T1~T8:1~8 a.m. alarm

contact capacity 220V AC,3A

Transmitting output

 

 A0

Without output

 A1

Current output(4~20)mA、(0~10)mA或(0~20)mA

 A2

Voltage output (0~5)V、(1~5)V

 A3

Voltage output (0~10)V

 A4

Other output

Supply power

 B0

Without supply power

 B1

supply24V DC, error less than±5%,more than 50mA

 B2

Supply 12 V DC, error less than±5%,more than 50mA

 B3

Supply precision voltage source,error less than ±0.2%,more than 40mA

 B4

Supply precision constant current source,error less than±0.2%,(0.1~10mA)

 B5

Other (please note when ordering)

Communication interface(Independent power supply, complete isolation,2400~19.2K, answering delay is less than 500μs)

 S0

Without communication interface

 S1

RS-232

 S2

RS-485

Instrument power

 V0

220V AC

 V1

24V DC

 V2

12V DC

 V3

Other

Communication interface(Independent power supply, complete isolation,2400~19.2K, answering delay is less than 500μs)

S0

Without communication interface

Non-standard features

  N

N means non-standard features

 

        【Next】      
 
Address: 6525 Room Kangde Building Shangdi six street NO 17, Haidian District,Beijing China Tel: 86-10-62975336 Fax: 86-10-62971247 E-mail:sales@wq-flowmater.com