Product details:

Quick Details

Place of Origin:

Beijing China (Mainland)

Brand Name:

Wanqun

Model Number:

LUGB

Nominal size:

DN250/300/350/400/500/600/700/800/900/1000

Medium temperature:

-40~+280 ℃

Measuring fluid:

Gas,liquid,

steam

Ambient temperature:

-40~+55℃

Output signal:

pulse,electricity

Nominal pressure:

≤2.5MPa

Output:

4~20mA or 0~10mA

Accuracy:

2.5

Power supply:

24VDC

Packaging & Delivery

Packaging Detail:

Carton or polywood cases.

Delivery Detail:

5 working days

Specifications

1.operates on the basis of Karman vortex street principle.
2.Medium:liquid,gas,steam
3.flange connection
4.intrinsic safety

LUGB vortex flow sensor flow range table

 

inside nominal diameter

DN(mm)

Flow range(m3/h)

liquid

gas

250

66~800

424~7500

300

94~1150

610~10500

350

128~1550

830~14500

400

168~2000

1084~19000

500

262~3100

1693~30000

600

377~4550

2438~42000

700

513~6200

3319~58000

800

669~8100

4334~76000

900

847~10000

5486~96000

1000

1046~12500

6772~120000

 

Dimensions

DN(mm)

H

latus rectum

no ball valve

250

~600

300

350

~650

400

500

~750

600

700

~850

800

900

~950

1000

 

Parameter Selection Table:

LUGB-

Pulse type, 24 VDC

DBLU-

4-20mA、24VDC

LUW-

(With intelligent LCD display meter)

J

Battery power, no output signal

M1

24VDC,4-20mA

 

 

Medium type and installation method

22

liquid      Flange clamp mounted

23

gas         Flange clamp mounted

24

steam       Flange clamp mounted

32

·            liquid      plug-in

33

gas         plug-in

34

steam       plug-in

 

Flange mounted caliber code

Caliber

(mm)

25

32

40

50

65

80

100

125

150

200

250

300

Code

02

03

04

05

06

08

10

12

15

20

25

30

 

Plug-in code basis

Caliber(mm)

250

300

350

400

500

600

700

800

900

1000

1100

1200

Code

 

025

030

035

040

050

060

070

080

090

100

110

120

 

Pressure

P1

2.5MPa

P2

4.0MPa

P3

  Others

 

Mounted flange material

C

  Carbon steel

S

  Stainless steel(1Cr18Ni9Ti)       321

M

  Stainless steel(OOCr17Ni14Mo2Ti)  316L

 

Body  material

S

  Stainless steel(1Cr18Ni9Ti)       321

M

  Stainless steel(OOCr17Ni14Mo2Ti)  316L

 

Explosion-proof type

N

  No anti-explosion type

D

  flame-proof type

I

·          Intrinsic safety type

 

 

Plug in the attachment

O

  Without a ball valve

Q

  With a ball valve

3.  Installation:

Make a pipe hole ,then welding the flange to the pipeline, and the speed sensor probe inserted in the center of the pipe, and fix the sensors on the flange.

 


 